Isolating Transformers
Isolation transformers are used in systems where effective voltage separation between circuits is essential. They provide protective separation of the primary and secondary windings, significantly increasing the operational safety of the installation and connected equipment. The separation of windings is achieved by using a split bobbin or an electrostatic shield, which additionally limits the transfer of disturbances and improves power quality.
- Enhanced electrical safety due to full circuit separation
- Protection of connected equipment against overvoltages, disturbances and damage
- Minimization of short-circuit and failure risks in low-voltage systems
- Ease of servicing and testing thanks to clear design and simple access to terminals
- Configurable number of taps, enclosure type and mounting method
- Railway industry
- Marine industry
- Power quality systems
- Oil & gas industry
- Heavy and mining industry
- Renewable energy sources
- Power electronics and drive systems
Custom Design
Manufacturing a transformer with parameters other than those specified in the catalogue is possible upon prior consultation. The manufacturer reserves the right to introduce changes resulting from the continuous development of its products. The transformer can also be manufactured in a different version upon prior agreement.
Download catalogue cards
Product code

Details:
| Design | Isolating transformers produced in accordance with requirements of EN/IEC 61558-2-4 |
|---|---|
| Insulation class |
B(130oC) - standard up to 5 kVA; F(155oC) - standard above 5 kVA |
| Climatic class /environmental class |
C1/E0 - land design; C2/E1 - maritime design |
| Ambient temperature | 40oC |
| Protection degree | IP 00 |
| Protection class | I |
| Frequency | 50/60 Hz |
| Vector group | Dyn5 - standard |
| Primary voltage | up to 1000 V |
| Secondary voltage | up to 500 V |
| Terminals | screw terminal blocks with the cross section from from 4 mm2 up to 150 mm2 or copper bus bars |
| Fastening | by means of angles |
Technical sketch
![]() |
| Design A for the power up to 5 kVA |
![]() |
| Design B for the power above 5 kVA |
Dimension table
Technical data of three-phase isolating transformers ET3o **
| Type | Power [kVA] |
L [mm] |
Bmax [mm] |
H [mm] |
d [mm] |
e [mm] |
f [mm] |
Weight [kg] |
Design |
|---|---|---|---|---|---|---|---|---|---|
| ET3o_* - 0,05 | 0,05 | 100 | 60 | 122 | 81 | 41 | 5 x 8 | 1,4 | A |
| ET3o_* - 0,15 | 0,15 | 125 | 71 | 140 | 100 | 55 | 5 x 8 | 2,6 | A |
| ET3o_* - 0,3 | 0,3 | 155 | 91 | 156 | 130 | 71 | 8 x 12 | 5,1 | A |
| ET3o_* - 0,5 | 0,5 | 195 | 102 | 185 | 173 | 82 | 8 x 11 | 7,5 | A |
| ET3o_* - 0,63 | 0,63 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 9,5 | A |
| ET3o_* - 0,8 | 0,8 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 10,5 | A |
| ET3o_* - 1,0 | 1,0 | 210 | 105 | 200 | 173 | 85 | 8 x 11 | 12 | A |
| ET3o_* - 1,5 | 1,5 | 240 | 131 | 226 | 198 | 105 | 11 x 15 | 16 | A |
| ET3o_* - 2,0 | 2,0 | 240 | 146 | 226 | 198 | 120 | 11 x 15 | 22 | A |
| ET3o_* - 2,5 | 2,5 | 261 | 140 | 239 | 198 | 114 | 11 x 15 | 26 | A |
| ET3o_* - 3,0 | 3,0 | 300 | 152 | 274 | 240 | 122 | 11 x 15 | 30 | A |
| ET3o_* - 4,0 | 4,0 | 300 | 165 | 274 | 240 | 135 | 11 x 15 | 38 | A |
| ET3o_* - 5,0 | 5,0 | 300 | 192 | 274 | 240 | 160 | 11 x 15 | 49 | A |
| ET3o_* - 6,3 | 6,3 | 360 | 230 | 365 | 310 | 125 | 11 x 15 | 47 | B |
| ET3o_* - 7,5 | 7,5 | 360 | 237 | 365 | 310 | 132 | 11 x 15 | 54 | B |
| ET3o_* - 8,0 | 8,0 | 360 | 247 | 365 | 310 | 142 | 11 x 15 | 60 | B |
| ET3o_* - 10,0 | 10,0 | 360 | 270 | 365 | 310 | 162 | 11 x 15 | 71 | B |
| ET3o_* - 12,5 | 12,5 | 420 | 255 | 425 | 370 | 158 | 11 x 15 | 82 | B |
| ET3o_* - 15,0 | 15,0 | 420 | 265 | 425 | 370 | 168 | 11 x 15 | 91 | B |
| ET3o_* - 16,0 | 16,0 | 420 | 265 | 425 | 370 | 168 | 11 x 15 | 92 | B |
| ET3o_* - 20,0 | 20,0 | 480 | 290 | 485 | 430 | 190 | 13 x 18 | 117 | B |
| ET3o_* - 22,5 | 22,5 | 480 | 300 | 485 | 430 | 200 | 13 x 18 | 129 | B |
| ET3o_* - 25,0 | 25,0 | 480 | 305 | 485 | 430 | 210 | 13 x 18 | 139 | B |
| ET3o_* - 30,0 | 30,0 | 480 | 315 | 485 | 430 | 220 | 13 x 18 | 154 | B |
| ET3o_* - 40,0 | 40,0 | 540 | 350 | 545 | 490 | 240 | 13 x 18 | 195 | B |
*) - for transformer design with climatic/environmental class C2/E1 (maritime design W/3 or tropical design T/3) the letter "M" or "G" ought to be added depending on final application
**) - this table was prepared basing on the technical specification for transformer with voltage ratio 400//400 operating under normal conditions. For other conditions and data the values may change
Note:
Manufacturer reserves the right to make changes resulting from the continuous development of products offered.
If requested in advance, it is possible to manufacture transformer in other version.
portable IP23