Safety Transformers
Safety transformers are designed to supply equipment with a voltage considered safe for the user and the installation. These are isolation transformers in which the secondary winding operates at a safety extra-low voltage level. Structurally, they correspond to isolation transformers, ensuring effective separation of loads from the mains and increasing the level of electric shock protection.
- High level of electric shock protection
- Supply voltage stabilization
- Reduction of overvoltages and short-circuit currents
- Increased resistance of the installation to damage and failures
- Railway industry
- Marine industry
- Power quality systems
- Oil & gas industry
- Heavy and mining industry
- Renewable energy sources
- Power electronics and drive systems
Custom Design
Manufacturing a transformer with parameters other than those specified in the catalogue is possible upon prior consultation. The manufacturer reserves the right to introduce changes resulting from the continuous development of its products. The transformer can also be manufactured in a different version upon prior agreement.
Download catalogue cards
Product code

Product for:
- Railway Industry
- Oil & Gas Industry
- Mining Industry
- Maritime Industry
- Heavy Industry
- Power Electronics and Drive Systems
- Power Quality
- Renewable Energy Sources
Details:
| Design: | Safety isolating transformers produced in accordance with requirements of EN/IEC 61558-2-6 |
|---|---|
| Insulation class: | B(130ºC) - standard up to 5 kVA, F(155ºC) - standard above 5 kVA |
| Climatic class /environmental class: |
C1/E0 - land design; C2/E1 - maritime design |
| Ambient temperature: | 40°C |
| Protection degree: | IP 00 |
| Protection class: | I |
| Frequency: | 50/60 Hz |
| Vector group: | Dyn5 - standard |
| Primary voltage: | up to 1000 V |
| Secondary voltage: | up to 50 V |
| Terminals: | screw terminal blocks with the cross section from from 4 mm2 up to 150 mm2 or copper bus bars |
| Fastening: | by means of angles |
Technical sketch
![]() |
| Design A for the power lower than 6,3 kVA |
![]() |
| Design B for the power 6,3 kVA and more |

Dimension table
Technical data of three-phase safety isolating transformers ET3o **
| Type | Power [kVA] |
L [mm] |
B [mm] |
H [mm] |
d [mm] |
e [mm] |
f [mm] |
Weight [kg] |
Design |
|---|---|---|---|---|---|---|---|---|---|
| ET3o_* - 0,05 | 0,05 | 100 | 60 | 122 | 81 | 41 | 5 x 8 | 1,4 | A |
| ET3o_* - 0,15 | 0,15 | 125 | 71 | 140 | 100 | 55 | 5 x 8 | 2,6 | A |
| ET3o_* - 0,3 | 0,3 | 155 | 91 | 156 | 130 | 71 | 8 x 12 | 5,1 | A |
| ET3o_* - 0,5 | 0,5 | 195 | 102 | 185 | 173 | 82 | 8 x 11 | 7,5 | A |
| ET3o_* - 0,63 | 0,63 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 9,5 | A |
| ET3o_* - 0,8 | 0,8 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 10,5 | A |
| ET3o_* - 1,0 | 1,0 | 210 | 105 | 200 | 173 | 85 | 8 x 11 | 12 | A |
| ET3o_* - 1,5 | 1,5 | 240 | 131 | 226 | 198 | 105 | 11 x 15 | 16 | A |
| ET3o_* - 2,0 | 2,0 | 240 | 146 | 226 | 198 | 120 | 11 x 15 | 22 | A |
| ET3o_* - 2,5 | 2,5 | 261 | 140 | 239 | 198 | 114 | 11 x 15 | 26 | A |
| ET3o_* - 3,0 | 3,0 | 300 | 152 | 274 | 240 | 122 | 11 x 15 | 30 | A |
| ET3o_* - 4,0 | 4,0 | 300 | 165 | 274 | 240 | 135 | 11 x 15 | 38 | A |
| ET3o_* - 5,0 | 5,0 | 300 | 192 | 274 | 240 | 160 | 11 x 15 | 49 | A |
| ET3o_* - 6,3 | 6,3 | 360 | 230 | 365 | 310 | 125 | 11 x 15 | 47 | B |
| ET3o_* - 7,5 | 7,5 | 360 | 237 | 365 | 310 | 132 | 11 x 15 | 54 | B |
| ET3o_* - 8,0 | 8,0 | 360 | 247 | 365 | 310 | 142 | 11 x 15 | 60 | B |
| ET3o_* - 10,0 | 10,0 | 360 | 270 | 365 | 310 | 162 | 11 x 15 | 71 | B |
| ET3o_* - 12,5 | 12,5 | 420 | 255 | 425 | 370 | 158 | 11 x 15 | 82 | B |
| ET3o_* - 15,0 | 15,0 | 420 | 265 | 425 | 370 | 168 | 11 x 15 | 91 | B |
| ET3o_* - 16,0 | 16,0 | 420 | 265 | 425 | 370 | 168 | 11 x 15 | 92 | B |
*) - for transformer design with climatic/environmental class C2/E1 (maritime design W/3 or tropical design T/3) the letter "M" or "G" ought to be added depending on final application
**) - this table was prepared basing on the technical specification for transformer with voltage ratio 400//24 operating under normal conditions. For other conditions and data the values may change
Note:
Manufacturer reserves the right to make changes resulting from the continuous development of products offered.
If requested in advance, it is possible to manufacture transformer in other version.
portable IP23