Separating transformers
Separating transformers are classic transformers in which the primary and secondary windings are separated by basic insulation. Unlike isolation transformers, they do not feature a split bobbin or a screen between the windings, while still maintaining galvanic separation of circuits. They are intended for supplying lighting circuits, control circuits and other systems requiring an additional level of protection against disturbances and overvoltages.
- Increased installation safety through galvanic separation of circuits
- Suppression of electromagnetic disturbances
- Protection against overvoltages and harmful impulses
- Stable operation of low-voltage loads
- Configuration flexibility thanks to selectable taps and mounting options
- Railway industry
- Marine industry
- Power quality systems
- Oil & gas industry
- Heavy and mining industry
- Renewable energy sources
- Power electronics and drive systems
Custom Design
Manufacturing a transformer with parameters other than those specified in the catalogue is possible upon prior consultation.
Download catalogue cards
Product code
Details:
| Design | Separating transformers are produced in accordance with requirements of: EN/IEC 61558-2-1; EN/IEC 60726 |
|---|---|
| Insulation class |
B(130oC) - standard up to 5 kVA; F(155oC) - standard above5 kVA |
| Climatic class /environmental class |
C1/E0 - land design; C2/E1 - maritime design |
| Ambient temperature | 40oC |
| Protection degree | IP 00 |
| Protection class | I |
| Frequency | 50/60 Hz |
| Vector group | Dyn5 - standard |
| Primary voltage | up to 1000 V |
| Secondary voltage | up to 1000 V |
| Terminals | screw terminal blocks with the cross section from from 4 mm2 up to 150 mm2 or copper bus bars |
| Fastening | by means of angles |
Technical sketch
![]() |
| Design A for the power up to 6,3 kVA |
![]() |
| Design B for the power above 6,3 kVA |
Dimension table
Technical data of three-phase separating transformers ET3S **
| Type | Power [kVA] |
L [mm] |
B [mm] |
H [mm] |
d [mm] |
e [mm] |
f [mm] |
Weight [kg] |
Design |
|---|---|---|---|---|---|---|---|---|---|
| ET3S_* - 0,05 | 0,05 | 100 | 60 | 122 | 81 | 41 | 5 x 8 | 1,4 | A |
| ET3S_* - 0,15 | 0,15 | 125 | 71 | 140 | 100 | 55 | 5 x 8 | 2,6 | A |
| ET3S_* - 0,3 | 0,3 | 155 | 91 | 156 | 130 | 71 | 8 x 12 | 5,1 | A |
| ET3S_* - 0,5 | 0,5 | 195 | 102 | 185 | 173 | 82 | 8 x 11 | 7,5 | A |
| ET3S_* - 0,63 | 0,63 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 9,5 | A |
| ET3S_* - 0,8 | 0,8 | 195 | 112 | 185 | 173 | 92 | 8 x 11 | 10,5 | A |
| ET3S_* - 1,0 | 1,0 | 210 | 105 | 200 | 173 | 85 | 8 x 11 | 12 | A |
| ET3S_* - 1,5 | 1,5 | 240 | 131 | 226 | 198 | 105 | 11 x 15 | 16 | A |
| ET3S_* - 2,0 | 2,0 | 240 | 146 | 226 | 198 | 120 | 11 x 15 | 22 | A |
| ET3S_* - 2,5 | 2,5 | 261 | 140 | 239 | 198 | 114 | 11 x 15 | 26 | A |
| ET3S_* - 3,0 | 3,0 | 300 | 152 | 274 | 240 | 122 | 11 x 15 | 30 | A |
| ET3S_* - 4,0 | 4,0 | 300 | 165 | 274 | 240 | 135 | 11 x 15 | 38 | A |
| ET3S_* - 5,0 | 5,0 | 300 | 192 | 274 | 240 | 160 | 11 x 15 | 49 | A |
| ET3S_* - 6,3 | 6,3 | 360 | 230 | 365 | 310 | 125 | 11 x 15 | 47 | A |
| ET3S_* - 7,5 | 7,5 | 360 | 237 | 365 | 310 | 132 | 11 x 15 | 54 | B |
| ET3S_* - 8,0 | 8,0 | 360 | 247 | 365 | 310 | 142 | 11 x 15 | 60 | B |
| ET3S_* - 10,0 | 10,0 | 360 | 270 | 365 | 310 | 162 | 11 x 15 | 71 | B |
*) - for transformer design with climatic/environmental class C2/E1 (maritime design W/3 or tropical design T/3) the letter "M" or "G" ought to be added depending on final applicationfor transformer design with climatic/environmental class C2/E1 (maritime design W/3 or tropical design T/3) the letter "M" or "G" ought to be added depending on final application
**) - this table was prepared basing on the technical specification for transformer with voltage ratio 400//400 operating under normal conditions. For other conditions and data the values may change
Note:
Manufacturer reserves the right to make changes resulting from the continuous development of products offered.
If requested in advance, it is possible to manufacture transformer in other version.
portable IP23