Three-phase power transformers ET3S** with the power between 40 and 1600 kVA class „H”
Power transformers are assigned for supplying power electronic devices, and for application in other industrial branches. In standard design, the transformers are adjusted to fastening by means of screwed angles.
If agreed, the transformers may have more tappings. The windings terminals may be placed on one side only, or on both sides of a transformer. Upon request, the transformers may be assembled in enclosures with the protection degree of IP 23, IP 44 and IP 54 with the possibility to insert supply cables through glands. Standard enclosures have powder coating - colour RAL 7032.
Details:
Design | Power transformers are produced in accordance with requirements of: EN/IEC 60726; EN/IEC 60076 |
---|---|
Insulation class | H(180°C) |
Climatic class /environmental class |
C1/E0 - land design; C2/E1 - maritime design |
Ambient temperature | 40oC |
Protection degree | IP 00 |
Protection class | I |
Frequency | 50/60 Hz |
Vector group | Dyn5 - standardowo |
Primary voltage | up to 1000 V |
Secondary voltage | up to 1000 V |
Terminals | screw terminal blocks or cable lugs or copper bus bars |
Technical sketch
Design for the power up to 160kVA | |
Design for the power above 160kVA |
Dimension table
Technical data of power transformers typ ET3S, insulation class H, voltage ratio 400V//400V**
Type | Power [kVA] |
L [mm] |
B [mm] |
H [mm] |
d [mm] |
e [mm] |
f [mm] |
Weight [kg] |
---|---|---|---|---|---|---|---|---|
ET3S_* - 40 | 40 | 540 | 320 | 545 | 490 | 220 | 13 x 18 | 171 |
ET3S_* - 50 | 50 | 540 | 350 | 545 | 490 | 240 | 13 x 18 | 202 |
ET3S_* - 63 | 63 | 540 | 370 | 545 | 490 | 260 | 13 x 18 | 235 |
ET3S_* - 75 | 75 | 690 | 390 | 615 | 590 | 210 | 13 x 18 | 271 |
ET3S_* - 80 | 80 | 690 | 400 | 615 | 590 | 220 | 13 x 18 | 288 |
ET3S_* - 100 | 100 | 690 | 380 | 615 | 590 | 230 | 13 x 18 | 330 |
ET3S_* - 115 | 115 | 690 | 410 | 615 | 590 | 260 | 13 x 18 | 380 |
ET3S_* - 120 | 120 | 720 | 400 | 715 | 620 | 250 | 17 x 25 | 390 |
ET3S_* - 125 | 125 | 720 | 410 | 715 | 620 | 250 | 17 x 25 | 400 |
ET3S_* - 160 | 160 | 720 | 440 | 715 | 620 | 290 | 17 x 25 | 495 |
ET3S_* - 200 | 200 | 980 | 460 | 860 | 700 | 375 | 4xfi17 | 660 |
ET3S_* - 225 | 225 | 980 | 460 | 860 | 700 | 375 | 4xfi17 | 690 |
ET3S_* - 250 | 250 | 1035 | 470 | 910 | 760 | 375 | 4xfi17 | 790 |
ET3S_* - 315 | 315 | 1080 | 480 | 980 | 760 | 375 | 4xfi17 | 915 |
ET3S_* - 400 | 400 | 1140 | 505 | 1010 | 760 | 394 | 4xfi17 | 1105 |
ET3S_* - 500 | 500 | 1245 | 545 | 1100 | 760 | 416 | 4xfi17 | 1350 |
ET3S_* - 630 | 630 | 1290 | 555 | 1210 | 760 | 416 | 4xfi17 | 1685 |
ET3S_* - 800 | 800 | 1410 | 600 | 1220 | 760 | 433 | 4xfi17 | 1980 |
ET3S_* - 1000 | 1000 | 1455 | 610 | 1420 | 760 | 433 | 4xfi17 | 2440 |
ET3S_* - 1250 | 1250 | 1620 | 650 | 1390 | 760 | 473 | 4xfi17 | 3080 |
ET3S_* - 1600 | 1600 | 1670 | 700 | 1500 | 760 | 473 | 4xfi17 | 3580 |
*) - for transformer design with climatic/environmental class C2/E1 (maritime design W/3 or tropical design T/3) the letter "M" or "G" ought to be added depending on final application
**) - this table was prepared basing on the technical specification for transformer with voltage ratio 400//400 at 50 Hz and operating under normal conditions. For other conditions and data the values may change
Note:
Manufacturer reserves the right to make changes resulting from the continuous development of products offered.
If requested in advance, it is possible to manufacture transformer in other version.